Technical characteristics
  • BrandMitsubishi Electric
  • Country of manufactureJapan
Description
series: Semi-industrial systems
type: external block,
R410A freon


Parameter / Model PUHZ-ZRP35VKA PUHZ-RP35VHA4 PUHZ-ZRP50VKA
Refrigerating capacity, kW 3.60 5.00
Power consumption (cooling), kW 0.790 1.070 1.430
Heating capacity, kW 4.10 6.00
Power consumption (heating), kW 0.860 1.120 1.570
Supply voltage (In, f, Hz) 220-240 V, 1 f, 50 Hz
Working current, And 4.01 6.16
Maximum working current, And 13:00
Consumption of air (max.), m3/h 2100
Noise level (max.), dB(A) 46
Weight, kg 42.0
Dimensions (SHKHDKHV), mm 600x800x323
Diameter of tubes (liquid) 6.35 (1/4)
Diameter of tubes (gas) 12.7 (1/2)
Maximum length of the highway, m 50
Maximum height difference, m 30
Factory gas station of coolant, kg 2.50
The guaranteed range of external temperatures (cooling) - 5 … +46 °C of DB (-15 °C at the installed panel of protection against wind)
The guaranteed range of external temperatures (heating) - 12 … +15 °C of WB

Parameter / Model PUHZ-RP50VHA4 PUHZ-ZRP60VHA PUHZ-RP60VHA4
Refrigerating capacity, kW 5.00 6.00
Power consumption (cooling), kW 1.550 1.780 1.600
Heating capacity, kW 6.00 7.00
Power consumption (heating), kW 1.660 2.040 1.820
Supply voltage (In, f, Hz) 220-240 V, 1 f, 50 Hz
Working current, And 6.16 6.61
Maximum working current, And 13:00 19:00
Consumption of air (max.), m3/h 2100 3300
Noise level (max.), dB(A) 46 48
Weight, kg 42.0 67.0
Dimensions (SHKHDKHV), mm 600x800x323 943x950x360
Diameter of tubes (liquid) 6.35 (1/4) 9.52 (3/8)
Diameter of tubes (gas) 12.7 (1/2) 15.88 (5/8)
Maximum length of the highway, m 50
Maximum height difference, m 30
Factory gas station of coolant, kg 2.50 3.50
The guaranteed range of external temperatures (cooling) - 5 … +46 °C of DB (-15 °C at the installed panel of protection against wind)
The guaranteed range of external temperatures (heating) - 12 … +15 °C of WB - 20 … +15 °C of WB

Parameter / Model PUHZ-ZRP71VHA PUHZ-FRP71VHA PUHZ-RP71VHA4
Refrigerating capacity, kW 7.10
Power consumption (cooling), kW 1.770 1.900
Heating capacity, kW 8.00
Power consumption (heating), kW 1.990 1.900
Supply voltage (In, f, Hz) 220-240 V, 1 f, 50 Hz
Working current, And 8.04
Maximum working current, And 19:00
Consumption of air (max.), m3/h 3300
Noise level (max.), dB(A) 48
Weight, kg 67.0
Dimensions (SHKHDKHV), mm 943x950x360
Diameter of tubes (liquid) 9.52 (3/8)
Diameter of tubes (gas) 15.88 (5/8)
Maximum length of the highway, m 50
Maximum height difference, m 30
Factory gas station of coolant, kg 3.50
The guaranteed range of external temperatures (cooling) - 5 … +46 °C of DB (-15 °C at the installed panel of protection against wind)
The guaranteed range of external temperatures (heating) - 20 … +15 °C of WB

Parameter / Model PUHZ-W50VHAR1 PUHZ-W50VHAR2 PUHZ-ZRP100VKA
Refrigerating capacity, kW 4.50 10:00
Power consumption (cooling), kW 1.530 2.600
Energy efficiency (EER) 4.10 0.00
Heating capacity, kW 5.00 11:20
Power consumption (heating), kW 1.220 2.610
Supply voltage (In, f, Hz) 220-240 V, 1 f, 50 Hz
Maximum working current, And 13:00 26.50
Consumption of air (max.), m3/h 3000 6600
Noise level (max.), dB(A) 46 51
Weight, kg 64.0 116.0
Dimensions (SHKHDKHV), mm 950x360x740 1338x1050x360
Diameter of tubes (liquid) 9.52 (3/8)
Diameter of tubes (gas) 15.88 (5/8)
Maximum length of the highway, m 50 75
Maximum height difference, m 30
Factory gas station of coolant, kg 1.70 5.00
The guaranteed range of external temperatures (cooling) - 5 … +46 °C of DB (-15 °C at the installed panel of protection against wind)
The guaranteed range of external temperatures (heating) - 15 … +35 °C of WB - 20 … +15 °C of WB

Parameter / Model PUHZ-RP100YKA PUHZ-ZRP125VKA PUHZ-RP125YKA
Refrigerating capacity, kW 10:00 12:50
Power consumption (cooling), kW 2.390 3.870 3.670
Heating capacity, kW 11:20 14:00
Power consumption (heating), kW 2.430 3.670 3.500
Supply voltage (In, f, Hz) 380-415 V, 3 f, 50 Hz 220-240 V, 1 f, 50 Hz 380-415 V, 3 f, 50 Hz
Maximum working current, And 8.00 26.50 9.50
Consumption of air (max.), m3/h 6600 7200
Noise level (max.), dB(A) 51 52
Weight, kg 124.0 116.0 126.0
Dimensions (SHKHDKHV), mm 1338x1050x360
Diameter of tubes (liquid) 9.52 (3/8)
Diameter of tubes (gas) 15.88 (5/8)
Maximum length of the highway, m 75
Maximum height difference, m 30
Factory gas station of coolant, kg 5.00
The guaranteed range of external temperatures (cooling) - 5 … +46 °C of DB (-15 °C at the installed panel of protection against wind)
The guaranteed range of external temperatures (heating) - 20 … +15 °C of WB

Parameter / Model PUHZ-ZRP100YKA PUHZ-ZRP100YKAR1 PUHZ-RP100VKA
Refrigerating capacity, kW 10:00
Power consumption (cooling), kW 2.600 2.390
Heating capacity, kW 11:20
Power consumption (heating), kW 2.610 2.430
Supply voltage (In, f, Hz) 380-415 V, 3 f, 50 Hz 220-240 V, 1 f, 50 Hz
Maximum working current, And 8.00 26.50
Consumption of air (max.), m3/h 6600
Noise level (max.), dB(A) 51
Weight, kg 124.0 116.0
Dimensions (SHKHDKHV), mm 1338x1050x360
Diameter of tubes (liquid) 9.52 (3/8)
Diameter of tubes (gas) 15.88 (5/8)
Maximum length of the highway, m 75
Maximum height difference, m 30
Factory gas station of coolant, kg 5.00
The guaranteed range of external temperatures (cooling) - 5 … +46 °C of DB (-15 °C at the installed panel of protection against wind)
The guaranteed range of external temperatures (heating) - 20 … +15 °C of WB

Parameter / Model PUHZ-ZRP125YKA PUHZ-ZRP125YKAR1 PUHZ-RP125VKA
Refrigerating capacity, kW 12:50
Power consumption (cooling), kW 3.870 3.670
Heating capacity, kW 14:00
Power consumption (heating), kW 3.670 3.500
Supply voltage (In, f, Hz) 380-415 V, 3 f, 50 Hz 220-240 V, 1 f, 50 Hz
Maximum working current, And 9.50 26.50
Consumption of air (max.), m3/h 7200
Noise level (max.), dB(A) 52
Weight, kg 126.0 116.0
Dimensions (SHKHDKHV), mm 1338x1050x360
Diameter of tubes (liquid) 9.52 (3/8)
Diameter of tubes (gas) 15.88 (5/8)
Maximum length of the highway, m 75
Maximum height difference, m 30
Factory gas station of coolant, kg 5.00
The guaranteed range of external temperatures (cooling) - 5 … +46 °C of DB (-15 °C at the installed panel of protection against wind)
The guaranteed range of external temperatures (heating) - 20 … +15 °C of WB

Parameter / Model PUHZ-ZRP140VKA PUHZ-RP140YKA PUHZ-ZRP140YKA
Refrigerating capacity, kW 14:00
Power consumption (cooling), kW 4.370 4.360 4.370
Heating capacity, kW 16:00
Power consumption (heating), kW 4.700 4.320 4.700
Supply voltage (In, f, Hz) 220-240 V, 1 f, 50 Hz 380-415 V, 3 f, 50 Hz
Maximum working current, And 28.00 13:00
Consumption of air (max.), m3/h 7200
Noise level (max.), dB(A) 52
Weight, kg 118.0 132.0
Dimensions (SHKHDKHV), mm 1338x1050x360
Diameter of tubes (liquid) 9.52 (3/8)
Diameter of tubes (gas) 15.88 (5/8)
Maximum length of the highway, m 75
Maximum height difference, m 30
Factory gas station of coolant, kg 5.00
The guaranteed range of external temperatures (cooling) - 5 … +46 °C of DB (-15 °C at the installed panel of protection against wind)
The guaranteed range of external temperatures (heating) - 20 … +15 °C of WB
Contact the seller
The external block cooling and heating with the inverter the Power Inverter PUHZ-RP_YHA 380B Series
The external block cooling and heating with the inverter the Power Inverter PUHZ-RP_YHA 380B Series
Shipping method
Payment method
Compare0
ClearSelected items: 0