(View map)
The monitor of the patient of YM6000 - P0BE personifies all latest developments of medical technologies. The dynamic linear module of pressure decrease in a cuff provides comfort to the patient at measurement of the ABP, reduces time and increases measurement accuracy for adults, children and newborns.
New SpO2 the module with the sensor lets know all advantages of a modern pulsoksimetriya.
Tabular and graphic indicators are available on the monitor till 24 o'clock.
The easy, compact monitor with a big set of the measured parameters. If the source of alternating current is unavailable, can eat from the battery. Options for pozitsionirovaniya: nastenny fastening and the rotating stand.
The displayed parameters
The monitor of the patient of YM6000 - P0BE is intended for multilateral measurement and control of vital signs of an organism, including an electrocardiography, measurement of the heart rate (HR), the pulse rate (PR), a noninvasive hemodynamometry (CD ‐ to NIBP) ‐ systolic (SYS), diastolic (DIA) and average arterial pressure (MAP or MEAN), measurement of a functional saturation by oxygen of an arterial blood - groove, invasive measurement of CD (IBP), breath, a kapnografiya (EtCO2 and InCO2) and measurement of temperature of patients – adults, children and newborns, in medical institutions of any type.
Scope
The device is used in the conditions of hospital (hospital), in departments of the general, intensive and critical care, operational, procedural. And also provides use in offices of individually practicing doctors, laboratories of a hypnotherapy, maternity homes and the centers for care of newborns.
Features:
- The high - quality TFT LCD monitor displays 6 curves and 10 numerical indicators.
- 6 buttons and one button wheel provide fast access to parameters and functions of the monitor.
- The rechargeable battery and the rotating stand (option) give the chance to function continuously during movement of the patient.
- Possibility of connection with the central station YM9000 (option) that allows to receive alarm signals automatically, besides to keep an event or a signal in real time, displaying or on the press. It is possible to look through the kept data made in the last 48 hours.
Technical characteristics of the monitor of the patient of YM6000 - POBE:
Name |
Parameters |
Screen size |
246.0х184.5 mm |
Diagonal |
12.1" |
Type screen/colour |
TFT with illumination by a fluorescent lamp with the cold cathode |
Permission |
800х600 px. |
Number of development of a signal |
To 6 |
Physical characteristics |
|
Monitor |
|
The size (ShhVhD) (including handles without the additional equipment) |
341kh305kh172mm |
Weight |
5,5 kg |
Fuses |
2 pieces. |
Current |
6.3 And |
Tension |
250 Century. |
Type |
IEC (5х20 mm) |
Printer (option) |
|
Type |
Thermal printer |
Weight |
150 g |
Permission |
8t/mm |
Number of channels |
From 1 to 2 |
Paper width |
50 mm |
Press speed |
25,0 and 50,0 mm / with |
Electric parameters |
|
Food |
100 - 240B, 50/60GTs, 63 - 110vamp |
Fuses |
Piece - 2, Current - 6.3 A, tension 250B, IEC type (5х20 mm) |
Rechargeable battery |
|
Type |
Ni - Mh |
Tension/capacity |
12 V / 3.8 Ach |
Recharge time |
12 watch with the monitor on/off. |
Operating time from the battery |
1 hour |
Compliance |
Directive 91/157 EEC |
Two batteries provide 2 hour of work without printer, external connections, alarms and one NIAD with measurement each 15 minutes at a temperature 25˚C (option) |
|
ECG |
|
Range |
20 - 250 beats/min |
Error |
±3 min1 or ±5% |
Number of assignments |
3/5 (assignments of I, II, III, aVR, aVL, aVF) |
The entering range on tension |
From ±0,5мВ to ±5мВ |
Signal duration |
40ms - 120ms (Q - S) |
Rate of display |
12.5, 25.0, 50.0 mm / c |
Respiration rate (spirography) |
|
Technique |
Thorax impedance |
Range |
0.3 - 120 dd / mines |
Accuracy |
±1 beats/min |
Electrodes |
RA - LA |
Electrode detachment |
It is defined and displayed |
Display rate of display |
6.25, 12.5, 25.0 mm / c |
NIAD |
|
Measurement range |
Adult/child of 30 - 260 beats/min, newborn 30 - 220 beats/min |
Error |
±2 beats/min or ±2% |
Technique |
Ostsillometrichesky testing |
Measurement modes |
Manual, car, continuous |
Manual mode |
Single measurement on pressing of the button |
Automatic measurement |
Automeasurement of CD with an interval of 1,2,3,5,10,15,20,30,45,60,90,120,180 min. |
Continuous mode |
A series of consecutive measurements within 5 minutes |
Range of measurement of CD of NIAD |
|
Systolic CD |
Adult/child 60 - 250 mm. rt. st Newborn 40 - 120 mm. rt. st |
Diastolic CD |
Adult/child 40 - 200 mm. rt. st Newborn 20 - 90 mm. rt. st |
Average arterial CD |
Adult/child 45 - 235 mm. rt. st Newborn 30 - 100 mm. rt. st |
Range of display of pressure |
0 - 300 mm. rt. st |
Display of pressure in compliance |
ANSI/AAMI SP10: 2002 + A1: 2003 |
SpO2 (blood hemoglobin saturation % oxygen) |
|
Range |
1% - 100% |
Blood stream |
0.03% - 20% |
Accuracy |
Adult – 70% - 100% ±2ед. Newborn - 70% - 100% ±2ед. |
Rate of display |
12.5, 25.0, 50.0 mm / c |
Pulse rate |
|
Range |
20 - 250 beats/min |
Accuracy |
±1% or ± 1 min1 |
Kapnografiya |
|
The measured and displayed parameters |
EtCO2, InCO2 |
Range |
0 – 150 mm Hg. |
Development time |
240 ms |
Delay time |
1,12ms |
Response of system |
1,32ms |
Warming up time |
At most 3 min. |
Rate of display |
6,5, 12.5, 25.0 mm / c |
Noise level |
Less than 41 dB at the noise level of 22 dB |
IAD |
|
Pulse rate |
|
Range |
20 - 250ud/mines |
Accuracy |
±1% or ±1 beats/min |
Invasive blood pressure (IBP) |
|
The displayed parameter |
P1, ABP P2, CVP, PAP, LAP |
Measurement range |
From - 50 - 300mm. rt. st. |
Entrance impedance |
More than 1 Ohm |
Sensor tension |
5B constant |
Entrance sensitivity of the sensor |
5mv/B/mm. rt. st. |
Dynamic volume of the sensor |
0,1mm3/100mm. rt. st. |
Range of calibration of zero |
±100мм. рт. ст. |
Calibration accuracy |
Less ±1мм. рт. ст. |
Sensor frequency |
25 Of Hz |
Accuracy of display of pressure |
±3мм. рт. ст. |
Scale |
P1 0 - 50, 0 - 100, 0 - 200, 0 - 300, car P2 0 - 20, 0 - 50, 0 - 100, 0 - 200, 0 - 300, car |
Rate of display |
12.5, 25.0, 50.0 mm / c |
Temperature |
|
Sensor type |
Thermistor |
The displayed parameters |
Temp1, Temp2 |
Range |
15 - 45. With |
Temperature |
- 20 ºС - 50 ºС ( - 4ºF - 122 ºF) |
Accuracy |
±0.1ºС (25 - 45ºС), ±0.2ºС (15 - 25ºС) or ±0.4ºС (15 - 25ºС) |
Relative humidity of air |
15% - 95% , without formation of condensate |
Height (pressure) |
700gpa - 1060gpa |
Trends |
|
Representation types |
Tabular, graphic |
Memory |
Only 1500 records Preservation on the chosen interval Preservation of alarms, mistakes Preservation of changes of NIAD |
Graphical representation |
Simultaneous representation 2kh schedules: - NIBP, P1/P2, SpO2, T1/T2 – ChSS/ChP, RESP, EtCO2 a possibility of the choice of the displayed parameters |
Tabular representation |
8 pages |
Intervals of saving data |
30s, 1, 2, 2.5, 5,10,15, 20, 30, 60, 120 min. |