The monitor of the patient of BM3 (Bionet, South Korea) perfectly are suitable for chambers of an intensive care, chambers of the patient, and also intensive care units of the general profile. The monitor of the patient of Bionet BM3 is equipped with an optimum set of functions.

Features:

  • ECG, SpO2, NIAD, Temperature, Breath.
  • Definition of an electrocardiostimulator on the ECG wave display
  • ST level, Ventricular ekstrasistoliya
  • 58 mm built - in thermal printer
  • Press of graphic and digital trends
  • 7" (15,5 cm) color flat LCD monitor of high resolution
  • Possibility of work in the autonomous mode on accumulators
  • Tone signal of SpO2
  • Memory of digital trends for 128 hours
  • It is intended both for adults, and for newborns
  • Direct data transmission during transportation of the equipment
  • Weight makes less than 3 kg, including the battery
  • Updating of the software on the Internet
  • Long and instant mode of check
  • Wireless and local communication (option)
  • 20 * 8 from a graphic trend
  • Support of HL7 (standard of an exchange, management and integration of electronic medical information) and MFER (medical rules of a raskodirovka of a format of fluctuations)

Technical characteristics:

Specification of the monitor

1.

Display

7’ LCD display (800х480)

2.

Dimensions

238 x 250 x 163, weight is 3,1 kg

3.

Indicators

To 4 waves (2 * EKG,  SpO2, Breath)

3rd - level sensor of alarm

ChSS, Pulsoksimetrichesky tone signal,

Level of a charge of batteries

Indicator of connection to a network

4.

Interface

Adapter of network food of 18 V, 2,5 A

The connector for synchronization with a difibliryator

- Level signal: from 0 to 5 V pulse

- Frequency of impulses: 100±10 ms

Network exit for a signal transmission

Alarming button

Exit of a direct current: 5B, 1 And

5.

Battery

Battery type: Lithium - ionic

Status of a charge of batteries

Time of autonomous work 2 hours (at a total charge)

6.

Printer

Press speed: 25,50 mm \ sec.

Paper size: 58 mm

Digital and graphic trenda

7.

Digital trends

Memory of digital trends: 128 hours

Interval of measurements: 1,5,15,30 minutes and 1 hour

Type of the table: one look for all tables

8.

Graphic trends

Duration of a graphic trend: 30, 60, 90 and 3,6,12 hours

9.

Versions of languages:

English, French, Spanish, Italian, German, Chinese

ECG

10.

Number of assignments

3 or 5 assignments (option) are chosen the user

11.

ChSS range 

from 30 to 300 beats/min

12.

Accuracy of measurements of ChSS 

±3 beats/min

13.

Analysis of ST of a segment

Yes

14.

Analysis of arrhythmias

Ventricular ekstrosistaliya,

Febrilyation,

Asistolichesky.

15.

Working range

от 0.5 до 40 Hz

16.

Strengthening choice

0.5, 1, 2, 4 mV/cm

17.

Mode of detection of a pacemaker

Detection of change of a form of a curve with its indication on the monitor screen, is chosen the user

18.

Resistance

> 5 мΩ

19.

Level of suppression of hindrances

> 90 dB at 50 or 60 Hz

20.

Range of an entrance signal

± 5 mV (= U) - ± 300 mV (~ U)

21.

Protection against a defibrillation

22.

Alarm of lack of assignment

Yes

SpO2 (pulsoksimetriya)

23.

Percentage interval of saturation

From 0 to 100

24.

Measurement range

0 ~ 254 blows/min.

25.

Extent of oxygenation

From 70 to 100 ± 2%

26.

Pulse measurement accuracy

±2 beats/min

27.

Tone signal

Yes

NIAD

28.

Measurement technique

Ostsillometrichesky

29.

Measurement mode

Manual mode: single measurement

Automatic mode: bucketed measurement of 1,2,3,4,5,10,15,20,30 minutes and 1,2,4,8 hour

To become: Constant within 5 minutes

30.

Display of pressure in a cuff

From 0 to 300 mm hg.

31.

Range of measurement of arterial pressure

Adults

- systolic from 50 to 260 mm hg.

- basic from 30 to 220 mm hg.

- diastolic from 20 to 200 mm hg.

Children

- systolic from 50 to 230 mm hg.

- basic from 30 to 190 mm hg.

- diastolic from 20 to 170 mm hg.

Newborns

- systolic from 50 to 120 mm hg.

- basic from 30 to 100 mm hg.

- diastolic from 20 to 90 mm hg.

32.

Degree of admission of manzhet

Adjustable

Respiration rate

33.

Measurement range

from 5 to 120 breath / in

34.

Measurement accuracy

± 3 breaths/min.

Temperature sensor

35.

Measurement range

from 15 °C to 45 °C

36.

Measurement accuracy

± 0,1 °C

37.

It is compatible to temperature sensors of YSI SERIES 400

Contact the seller