- BrandCattani
tel. 373 (69) 252052
Email:
adles - srl@adles. md
Website:
adles. md
Website: adles. all. biz
Micro - Smart in one embodiment, can be operated in two versions. He is able to provide one of the dental unit aspiration, but the expansion of dental clinics, equipping its second plant, Micro - Smart will automatically go to work at full capacity and can provide reliable aspiration of two dental units.
This aspirator vacuum level can be adjusted in the range from 0 to 200 millibar.
For his work does not require a connection to the water mains. In Micro - Smart automatically regulated vacuum level: by increasing the number of installations simultaneously using suction, it increases the engine rotational speed, maintaining thereby a constant vacuum level. On the other hand reduces the number of revolutions with decreasing the number of simultaneous installations included. Consequently, even the power consumption is proportional to the suction load, turning out a much lower when compared to conventional systems, which allows also to save energy.
Employment of dental suction pump Micro - Smart delivers performance comparable to conventional units, at the same time it has a much smaller dimensions in relation to traditional suction units of similar capacity.
Micro - Smart program controls the temperature, current strength and the level of vacuum at the temperature higher than normal, the apparatus automatically reduces the speed of the motor of the vacuum pump, thus contributing, normalization of temperature and subsequent automatic restoration of the original mode. Likewise the unexpected formation of more than a stipulated amount of aspirating the mixture, the centrifuge apparatus, serving as separator, immediately begins more intensive circulation of excess fluid, increasing the discharge into the sewers until the return to normal operation. This principle of automatic control helps to avoid the stop of aspiration, and at the same time reduces the overload of the unit.
The display Micro - Smart displays special signals representative of any deviation in the work. Technical facility Compressor and suction must be installed in the room in which clients are denied access, unauthorized persons and medical personnel are not trained for the purpose. If highlight such placement is not possible, the units must be protected by a special casing, remove that it is difficult to prevent accidental contact, which may cause electric shock, burns (when touching the heated during operation node), a fire or explosion (unlikely but it is not excluded), the air pollution and / or fluid leakage.
Benefits
- economical
- effective
- Clever
The number of units (pieces) | 2 |
Output (l / min) | 900 |
The vacuum level (mm / h) | 2100 |
Noise level (dB (A)) | 67 |
Voltage | 220 V, 50/60 Hz |
Power, kWt) | 1.12 |
Net Weight (kg) | 22 |
Size (mm) | 380 x 350 x 600 |