- BrandНефтехимавтоматика АО БСКБ
- Country of manufactureRussia
The device is intended for preparation of samples from geosynthetic materials at action on them cyclic loading according to GOST 32490-2013, ODM 218.5.006-2010.
Device design monoblock, floor type.
AUTOMATIC FUNCTIONS OF THE DEVICE:
- consolidation of the lower layer of crushed stone;
- performance of the set number of cycles of loading of a sample with a frequency of 1 Hz with the set amplitude (by default 200 cycles, 500 kPa);
- storing of schedules of loading in non-volatile memory of the device, viewing and transfer on the personal computer on RS-232;
- automatic transfer of results of tests from the device on a radio channel to the personal computer through a subsystem of the wireless Lintel-Link interface in the database of the laboratory research Lintel-Lys system for the subsequent calculations of additional parameters and statistical processing.
ATTENTION: "Lintel-Link" and "Lintel-Lys" are got separately.
SPECIFICATIONS:
1. lower value of load of a sample: 10±10 kPa;
2. top value of load of a sample: 500±10 kPa;
3. frequency of cyclic loading: 1 Hz;
4. Food parameters:
- tension (220+22/-33)B;
- frequency (50±1) of Hz;
- power consumption, no more:
- in a waiting mode: 200 V · And;
- in the test mode: 400 V · And;
- in the energy saving mode: 30 V · And;
5. Overall dimensions, no more: 760х900х1100 mm.
6. Mass of the device, no more:
- without equipment: 130 kg;
- with equipment: 145 kg;
7. Warranty period of operation of the device: 12 months.
COMPLETENESS:
Name |
Quantity |
Note |
Device of cyclic loading |
1 |
|
Documentation |
||
Operation manual |
1 |
|
Passport |
1 |
|
The manometer of excessive pressure (MT), the vacuum gage (VP), manovakuummetr (MVP), a naporomer (NP), the draft gage (TP), a tyagonaporomer (TNP) showing. Passport |
1 |
|
The passport of the vessel working under pressure (PB-230/10 model) |
1 |
|
The packing list on a receiver vertical PB-230/10 |
1 |
|
Passport. Safety valve |
1 |
|
Compressor Jun-Air. Operation manual |
1 |
|
5um filter regulator. Installation and maintenance instructions |
1 |
|
Spare parts |
||
Insert fusible H520-8A 250B |
2 |
|
Accessories |
||
Box of preparation of samples |
||
Consolidation plate |
||
Connecting RS-232 cable |
1 |
by the separate order |
"Half-wave dipole" antenna |
1 |
|
Additional equipment |
||
Receiver vertical PB-230/10 |
1 |
by the separate order |
Jun-Air Model 6-4 compressor |
1 |
by the separate order |
The gages recommended for certification
Name of means |
Limits of measurements |
Accuracy class |
Appointment at certification of the device |
Note |
Dynamometer ATSDS-10/1I-1 |
10 kN |
(±0,24%) |
Measurement of effort |
On dopolnitel- to Nome to the order |