Currency MDL
Device electrosurgical Force Triad – Medical Store, TOO | all.biz
Buy Device electrosurgical Force Triad
Device electrosurgical Force Triad

Device electrosurgical Force Triad

In stock
Reconfirm the price with seller
Payment:
Shipping:
Seller
Kazakhstan, Almaty
(View map)
+7(7 
Display phones
9
9 years on Allbiz
Quickly responds
Description

The device electrosurgical Force Triad monopolar, bipolar and elektroligiruyushchy with monitoring of resistance of fabrics.

General characteristic:

  • The device combined electrosurgical and elektroligiruyushchy mikrokontrolerny with monitoring of resistance of fabrics complete with electrodes and accessories.

Safety of work:

  • Nominal frequency in all modes 472 kHz. Monitoring of resistance of tissues of the patient in a surgery field through an active electrode not less than 3300 times a second (the patented system) maintains constancy of the power given to tissues of the patient, despite changes of resistance of fabrics including in the contactless modes.
  • Therefore the assessment of effective power of the device is equal to 98 - 99% .
  • Power in watts, as the main parameter regulated by the user (not tension, not conventional dimensionless units, not % of the maximum indicators). Constancy of surgical effect at sharply reduced general power and lack of need of changes in settings thanks to automatic control of a power output of a coagulator at the level established by the surgeon ± 5% .
  • Protection against excessive power (switching off when exceeding power more than for 35% ). An exception of peak increases of power or tension at the generator exit at inclusion and switching off.
  • The built - in system of an iskropodavleniye in cutting modes and contact coagulation. Management of the modes by means of three touch screens. A conclusion to touch screens of the necessary user menu at recognition of the tool.
  • Recognition of tools video cameras in sockets on the front panel (7 exits).
  • Possibility of connection to 4 tools at the same time, including two elektroligiruyushchy. Monitoring of efficiency of contact of a neutral electrode – avoidance of burns from the patient's plate (the patented system). Adaptivity of system of monitoring of a neutral electrode to resistance of tissues of the specific patient. Automatic self - testing of parts of the device. Built - in system of suppression of currents of leak. Leak current high - frequency: Mean square value in the bipolar modes less than 59.2 ma; Mean square value in monopolar and alloying the modes less than 100 ma.
  • Availability of error codes for service. Alarm signals (with interruption in supply of power on generator exits): At emergence of codes of mistakes; At change of an impedance of fabrics under a single - section neutral electrode on 20 Ohms and more; At an impedance of fabrics under a two - section neutral electrode less than 5 Ohms or more than 135 Ohms; At change of initially measured impedance of fabrics under a two - section neutral electrode more than for 40% ; At disturbance of contact with the patient's plate.

Overall performance:

Monopolar section:

  • Section with smooth edges without scab: Power. Not less than 300 W in the range from 0 to 4000 W;
  • Cross factor not less than 1,42. A section with coagulation of edges: Power is not less than 200 W with the broad range of resistance of fabric;
  • Cross factor not less than 2,7. The dissection mode with a hemostasis: Power is not less than 200 W with the broad range of resistance of fabric; Cross factor not less than 4,3. Contactless coagulation (the mode has two modifications): Power is not less than 120 W;
  • Cross factor 5,55 or 6,5.

Bipolar coagulation (coagulation by means of a bipolar clip or other holding tools):

  • Small, standard and macro - the bipolar modes: Power is not less than 95 W; Cross factor not less than 1,5. Autobipolyarny function for all three bipolar modes with a possibility of programming of the management detained start and a self - locking device on an impedance cut - off.
  • The built - in monitor of bipolar current with feedback for the surgeon. 4. Exact selection of power by the user with a step of 1 W at low capacities, with a step no more than 5 W on averages and 10 W big capacities. Option for SMART SOCKETS of tools: power zones with the programmed indicators and an opportunity for the surgeon of change of power from the sterile field without the aid of personnel. Storing of the last before switching off of settings of power. Control of the generator from a pedal and from the electrosurgical handle. Standard ability of work with an argonoplazmenny prefix, at its availability. The electrosurgical handle (the holder of an electrode) who does not have internal cavities with a cable and a 3 - zuby fork.
  • The electrosurgical handle (the holder of an electrode) three - push - button, with the power switch, with an antiprigarny electrode and the SMART FORK on a cable. Monopolar electrodes with an antiprigarny covering. Safe sticky two - section plates of the patient – a peripheral link of system of tracking contact of skin and a plate for the purpose of an exception of burns. The extender of monopolar electrodes for work in the depth of a wound. Bipolar tweezers and connecting cables to them. Variety of the alloying tools. Monopolar (three - keyboard), both bipolar, and elektroligiruyushchy pedals. The special mobile cart for the electrosurgical equipment in one design with the device. Overall dimensions of the device: 458 (width) x 255 (height) x 508 (length) of mm.
  • Weight is 13.6 kg.
Contact the seller
Device electrosurgical Force Triad
Device electrosurgical Force Triad
Shipping method
Payment method
Compare0
ClearSelected items: 0